Sharon & Amber

Job Details

  • Proper recovery of refrigerant from old system
  • Use existing control wiring
  • Use existing electrical
  • New condensate pump
  • New precast pad & snow legs under unit
  • Remove and haul away old system
  • Flare out throat on plenum
  • Use existing refrigerant lines
  • Flush with RX11 flush
  • Reuse existing media air cleaner & humidifier
  • Crushed stone to level pad
Before
After
Brian & Nancy

Job Details

  • Remove existing geothermal system
  • Install Water Furnace Series 5 NDV038 ground source heat pump with a variable speed fan, dual speed compressor in basement
  • Install pad for noise isolation
  • New connections made to the existing ductwork with fiberboard ducts
  • Tie into the current geothermal loop with a new Water Furnace 2 pump flow center for proper loop circulation
  • Install Water Furnace TPCC32U01 programmable thermostat
  • Install Aurora Advanced Control Board
  • This system uses R-410A, the ozone friendly refrigerant
  • Install Merv 11 filter
Before
After
Joseph

Job Details

  • Remove the existing geothermal unit and install a WaterFurnace NDV072, ground source heat pump with a variable speed fan, and a two stage scroll compressor
  • New 15KW heater package
  • New foam pad for noise isolation
  • New expansion tank
  • New connections made to the existing ductwork with fiberboard ducts and tie into the existing geothermal loop with a new WaterFurnace two pump flow center for proper loop circulation
  • New Ecobee 5 WiFi Thermostat supplied to control the system
Before
After
Ray & Maryann

Job Details

  • Remove an existing water damaged geothermal heat pump and install a WaterFurnace NDV064, 5-ton ground source heat pump with a variable speed fan, and a two stage compressor
  • A solenoid water valve will be connected to the existing open loop piping, and the desuperheater will be connected to the existing water heater
  • Unit includes a cupronickel coaxial heat exchanger for durability as well as an aluminum air coil
  • This sytem uses R-410A, the ozone friendly refrigerant
Before
After
Chester & Sandy

Job Details

  • Remove entire supply trunk and install fully insulated ductwork in loft/new supply runs above floor
  • Increase return air as needed. Unit in loft will be installed with emergency auxiliary drain pan and drain lines to the outside
  • Furnish and install an emergency water detection cutoff switch as an additional safety, should both the regular and emergency drain pans become clogged
  • Remove and haul away old equipment
  • Run new control wiring
  • Run new electrical
  • New outdoor disconnect box
  • Outdoor heavy duty leveled composite pad with bump up legs
  • Install new balancing dampers on all supply runs/add new supply kitchen/laundry
  • Proper recovery of refrigerant from old system
  • Run new properly sized and insulated refrigerant lines enclosed in slim duct on exterior of home
  • Use existing electrical panel
  • Hook up to condensate system with emergency drain pan and emergency water detection cutoff switch
Before
After
Paul & Lori

Job Details

  • Run properly insulated refrigerant lines
  • Remove and haul away old equipment
  • New outdoor disconnect
  • Stone base/new outdoor pad and bump up legs
  • New pump/hook to current condensate drain system
  • Proper recovery of refrigerant from old system
  • Add refrigerant for proper operation
  • Use some existing control wiring
  • Use existing electrical panel
Before
After
Kathleen

Job Details

  • Run new refrigerant lines
  • Remove and haul away old equipment
  • Add refrigerant for proper operation
  • Install a filter rack
  • New precast pad for unit to sit on
  • Flare out throat on plenum
  • New Honeywell T-6 Thermostat with new system
  • Use existing indoor electrical wire (includes new safety shutoff switches)
  • Use existing control wiring
  • Furnace will vent to existing exhaust pipes
  • New condensate pump
  • Crushed stone to level outdoor pad
  • Fiberboard duct connections
After
Scott & Karen

Job Details

  • Use existing refrigerant lines
  • Remove and haul away old equipment
  • Add refrigerant for proper operation
  • Proper recovery of refrigerant from old system
  • Install a filter rack
  • Condensate drain gravity to sump
  • Use existing indoor electrical wire (includes new safety shutoff switches)
  • Use existing control wiring
  • Furnace will vent to existing exhaust pipes
  • Fiberboard duct connections to existing ducts
  • Remove existing humidifier
Before
After
Glenn

Job Details

  • Remove existing geothermal system
  • Install Water Furnace Series 5 NDV064 ground source heat pump with a variable speed fan, dual speed compressor in basement
  • Intellistart included (extends compressor life/reduces amp draw/provides quieter start up
  • Pad for noise isolation
  • New connections will be made to the existing ductwork with fiberboard ducts
  • Tie into the current geothermal loop with a new Water Furnace 2 pump flow center for proper loop circulation
  • New Ecobee Thermostat
  • This system uses R-410A, the ozone friendly refrigerant
  • Merv 11 Filter
  • Includes all related plumbing and electrical work for system operation
After
Tyler

Job Details

  • Remove existing geothermal system
  • Install Water Furnace Series 5 NDV049 ground source heat pump with a variable speed fan, dual speed compressor in basement
  • Intellistart option included
  • Desuperheater included
  • Install new 50-gallon electric water heater and use current water as a preheat tank
  • Expansion tank
  • Pad for noise isolation
  • New connections will be made to the existing ductwork with fiberboard ducts
  • Tie into the current geothermal loop with a new Water Furnace 2 pump flow center for proper loop circulation
  • IntelliZone2 Control Panel with main thermostat 2 zone capacity system, one main color touch screen stat and 1 sensor stat. Two new damper & motors
  • This system uses R-410A, the ozone friendly refrigerant
  • Merv 11 Filter
  • Includes all related plumbing and electrical work for system operation
Before
After
Randall

Job Details

  • Use existing refrigerant lines
  • Remove and haul away old equipment
  • Add refrigerant for proper operation
  • Proper recovery of refrigerant from old system
  • Install a filter rack
  • Flush refrigerant lines with RX-11 flush
  • Crushed stone to level outdoor pad
  • Fiberboard duct connections to existing ducts
  • Use existing indoor electrical wire (includes new safety shutoff switches)
  • Use existing control wiring
  • Furnace will vent to existing chimney
  • New condensate pump
  • New precast pad for unit to sit on
  • Secondary drain pan with safety switch
Before
After
Jack

Job Details

  • Supply & install a Honeywell TH8321 WF thermostat
  • New powered damper installed in new attic duct
  • Supply trunk of R-8 fiberboard duct that will be installed in the attic
  • Branch ducts of R-8 insulated flexible duct
  • New supply register in master ceiling
  • New supply register in closet hallway
  • Patch existing holes in remainder of second floor zone
  • Includes all necessary wiring and ducting
Before
After