Sharon & Amber
Job Details
- Proper recovery of refrigerant from old system
- Use existing control wiring
- Use existing electrical
- New condensate pump
- New precast pad & snow legs under unit
- Remove and haul away old system
- Flare out throat on plenum
- Use existing refrigerant lines
- Flush with RX11 flush
- Reuse existing media air cleaner & humidifier
- Crushed stone to level pad
Before
After
Brian & Nancy
Job Details
- Remove existing geothermal system
- Install Water Furnace Series 5 NDV038 ground source heat pump with a variable speed fan, dual speed compressor in basement
- Install pad for noise isolation
- New connections made to the existing ductwork with fiberboard ducts
- Tie into the current geothermal loop with a new Water Furnace 2 pump flow center for proper loop circulation
- Install Water Furnace TPCC32U01 programmable thermostat
- Install Aurora Advanced Control Board
- This system uses R-410A, the ozone friendly refrigerant
- Install Merv 11 filter
Before
After
Joseph
Job Details
- Remove the existing geothermal unit and install a WaterFurnace NDV072, ground source heat pump with a variable speed fan, and a two stage scroll compressor
- New 15KW heater package
- New foam pad for noise isolation
- New expansion tank
- New connections made to the existing ductwork with fiberboard ducts and tie into the existing geothermal loop with a new WaterFurnace two pump flow center for proper loop circulation
- New Ecobee 5 WiFi Thermostat supplied to control the system
Before
After
Ray & Maryann
Job Details
- Remove an existing water damaged geothermal heat pump and install a WaterFurnace NDV064, 5-ton ground source heat pump with a variable speed fan, and a two stage compressor
- A solenoid water valve will be connected to the existing open loop piping, and the desuperheater will be connected to the existing water heater
- Unit includes a cupronickel coaxial heat exchanger for durability as well as an aluminum air coil
- This sytem uses R-410A, the ozone friendly refrigerant
Before
After
Chester & Sandy
Job Details
- Remove entire supply trunk and install fully insulated ductwork in loft/new supply runs above floor
- Increase return air as needed. Unit in loft will be installed with emergency auxiliary drain pan and drain lines to the outside
- Furnish and install an emergency water detection cutoff switch as an additional safety, should both the regular and emergency drain pans become clogged
- Remove and haul away old equipment
- Run new control wiring
- Run new electrical
- New outdoor disconnect box
- Outdoor heavy duty leveled composite pad with bump up legs
- Install new balancing dampers on all supply runs/add new supply kitchen/laundry
- Proper recovery of refrigerant from old system
- Run new properly sized and insulated refrigerant lines enclosed in slim duct on exterior of home
- Use existing electrical panel
- Hook up to condensate system with emergency drain pan and emergency water detection cutoff switch
Before
After
Paul & Lori
Job Details
- Run properly insulated refrigerant lines
- Remove and haul away old equipment
- New outdoor disconnect
- Stone base/new outdoor pad and bump up legs
- New pump/hook to current condensate drain system
- Proper recovery of refrigerant from old system
- Add refrigerant for proper operation
- Use some existing control wiring
- Use existing electrical panel
Before
After
Kathleen
Job Details
- Run new refrigerant lines
- Remove and haul away old equipment
- Add refrigerant for proper operation
- Install a filter rack
- New precast pad for unit to sit on
- Flare out throat on plenum
- New Honeywell T-6 Thermostat with new system
- Use existing indoor electrical wire (includes new safety shutoff switches)
- Use existing control wiring
- Furnace will vent to existing exhaust pipes
- New condensate pump
- Crushed stone to level outdoor pad
- Fiberboard duct connections
After
Scott & Karen
Job Details
- Use existing refrigerant lines
- Remove and haul away old equipment
- Add refrigerant for proper operation
- Proper recovery of refrigerant from old system
- Install a filter rack
- Condensate drain gravity to sump
- Use existing indoor electrical wire (includes new safety shutoff switches)
- Use existing control wiring
- Furnace will vent to existing exhaust pipes
- Fiberboard duct connections to existing ducts
- Remove existing humidifier
Before
After
Glenn
Job Details
- Remove existing geothermal system
- Install Water Furnace Series 5 NDV064 ground source heat pump with a variable speed fan, dual speed compressor in basement
- Intellistart included (extends compressor life/reduces amp draw/provides quieter start up
- Pad for noise isolation
- New connections will be made to the existing ductwork with fiberboard ducts
- Tie into the current geothermal loop with a new Water Furnace 2 pump flow center for proper loop circulation
- New Ecobee Thermostat
- This system uses R-410A, the ozone friendly refrigerant
- Merv 11 Filter
- Includes all related plumbing and electrical work for system operation
After
Tyler
Job Details
- Remove existing geothermal system
- Install Water Furnace Series 5 NDV049 ground source heat pump with a variable speed fan, dual speed compressor in basement
- Intellistart option included
- Desuperheater included
- Install new 50-gallon electric water heater and use current water as a preheat tank
- Expansion tank
- Pad for noise isolation
- New connections will be made to the existing ductwork with fiberboard ducts
- Tie into the current geothermal loop with a new Water Furnace 2 pump flow center for proper loop circulation
- IntelliZone2 Control Panel with main thermostat 2 zone capacity system, one main color touch screen stat and 1 sensor stat. Two new damper & motors
- This system uses R-410A, the ozone friendly refrigerant
- Merv 11 Filter
- Includes all related plumbing and electrical work for system operation
Before
After
Randall
Job Details
- Use existing refrigerant lines
- Remove and haul away old equipment
- Add refrigerant for proper operation
- Proper recovery of refrigerant from old system
- Install a filter rack
- Flush refrigerant lines with RX-11 flush
- Crushed stone to level outdoor pad
- Fiberboard duct connections to existing ducts
- Use existing indoor electrical wire (includes new safety shutoff switches)
- Use existing control wiring
- Furnace will vent to existing chimney
- New condensate pump
- New precast pad for unit to sit on
- Secondary drain pan with safety switch
Before
After
Jack
Job Details
- Supply & install a Honeywell TH8321 WF thermostat
- New powered damper installed in new attic duct
- Supply trunk of R-8 fiberboard duct that will be installed in the attic
- Branch ducts of R-8 insulated flexible duct
- New supply register in master ceiling
- New supply register in closet hallway
- Patch existing holes in remainder of second floor zone
- Includes all necessary wiring and ducting
Before
After